  90 kv microfocus x-ray source l9421-02 features applications [applicable objects] ?lectronic component ?rinted circuit board ?lastic component ?etal component focal spot size: 5 m (at 4 w) the focal spot of 5 m of the sealed type x-ray tube enables sharp and clear x-ray images even at a high magnification. easy handling fully operable from an external pc. serial port control (rs-232c) one package of a sealed type x-ray tube, a high-voltage power supply and a control function. non-destructive inspection x-ray ct in-line x-ray inspection x-ray source
specifications general x-ray tube x-ray control part 1 see the graph of the tube current operational range. note: input voltage (dc) power consumption (max.) operating ambient temperature storage temperature operating and storage humidity weight conformance standards operation high voltage power supply +24 96 +10 to +40 0 to +50 below 85 (no condensation) approx. 10 ce (emc: iec 61326-1, group1, class a) continuous built-in v w c c % kg description / value unit parameter x-ray tube x-ray tube cooling method x-ray tube window material / thickness target material tube voltage operational range tube current operational range 1 maximum output x-ray focal spot size x-ray beam angle (coned) focus to object distance (fod) sealed type convection cooling beryllium / 150 tungsten 20 to 90 10 to 200 (8 w max.) 8 7 (5 m at 4 w) 39 9.5 m kv a w m degrees mm description / value unit parameter function protection external control applicable os computer operating conditions tube voltage and tube current preset / auto warm-up interlock rs-232c windows 2000 professional, xp professional cpu: intel pentium or higher, memory: 64 mb or more description unit parameter pre-caution to use 1. x-ray emitted from this device is harmful for human body. and it should be necessary for the operator to protect himself/her self from it. 2. during an operation, the x-ray tube unit should be installed in the x-ray shielded facility or area in order to avoid any x- ray leakage. also the interlock system in x-ray control unit should be always used in order to avoid any misoperation. ! operational caution the product may be subject to governmental occupational radiation hazardous regulation therefore the necessary application must be field according to the local regulation.
tube current operational range dimensional outline (unit: mm) tlsoa0093ed tlsob0100ea tube current ( a) tube voltage (kv) 200 150 20 kv to 40 kv range: reference data 250 100 50 0 40 80 60 20 90 power dc 24 v interlock-1 interlock-2 rs-232c * connection cables aren , t included. 85.5 1.0 cooling fan x-ray focal spot 39 x-ray beam angle 4-m6 depth 8 (mounting screw holes) 4-m6 depth 8 (mounting screw holes) 171 1 12 44 85 min. (reference)* 31 100 2-m3 depth 4 fod 9.5 gnd 195 1 291.5 1 78 1 23.5 9.5 167 1 147 0.5 147 0.5 x-ray focal spot
txpr1011e01 mar. 2012 ip windows is a registered trademark of microsoft corporation in the united states and/or other countries. other product and software names mentioned herein may be either registered trademarks or trademarks of their respective owners. information furnished by hamamatsu is believed to be reliable. however, no responsibility is assumed for possible inaccuracies or omissions. specifications are subject to change without notice. no patent rights are granted to any of the circuits described herein. ?2012 hamamatsu photoni cs k.k. subject to local technical requirements and regulations, availability of products included in this promotional material may var y. please consult with our sales office. hamamatsu photonics k.k. hamamatsu photonics k.k., electron tube division 314-5, shimokanzo, iwata city, shizuoka pref., 438-0193, japan, telephone: (81)539/62-5248, fax: (81)539/62-2205 u.s.a.: hamamatsu corporation: 360 foothill road, p. o. box 6910, bridgewater. n.j. 08807-0910, u.s.a., telephone: (1)908-231-0960, fa x: (1)908-231-1218 e-mail: usa@hamamatsu.com germany: hamamatsu photonics deutschland gmbh: arzbergerstr. 10, d-82211 herrsching am ammersee, germany, telephone: (49)8152-375-0, f ax: (49)8152-2658 e-mail: info@hamamatsu.de france: hamamatsu photonics france s.a.r.l.: 19, rue du saule trapu, parc du moulin de massy, 91882 massy cedex, france, telephone: (3 3)1 69 53 71 00, fax: (33)1 69 53 71 10 e-mail: infos@hamamatsu.fr united kingdom: hamamatsu photonics uk limited: 2 howard court, 10 tewin road welwyn garden city hertfordshire al7 1bw, united kingdom, teleph one: 44-(0)1707-294888, fax: 44(0)1707-325777 e-mail: info@hamamatsu.co.uk north europe: hamamatsu photonics norden ab: smidesv ? gen 12, se-171-41 solna, sweden, telephone: (46)8-509-031-00, fax: (46)8-509-031-01 e-mail: info@hamamatsu.se italy: hamamatsu photonics italia: s.r.l.: strada della moia, 1/e, 20020 arese, (milano), italy, telephone: (39)02-935 81 733, fax: (39)02-935 81 741 e-mail: info@hamamatsu.it china: hamamatsu photonics (china) co., ltd.: 1201 tower b, jiaming center, no.27 dongsanhuan beilu, chaoyang district, beijing 10002 0, china, telephone: (86)10-6586-6006, fax: (86)10-6586-2866 e-mail: hpc@hamamatsu.com.cn www.hamamatsu.com related products fos (fiber optic plate coated with x-ray scintillator) structure the fos is an optical device for x-ray imaging, fabricated by coating an x-ray scintillator material over a fiber optic plate c onsisting of more than tens of million glass fibers each a few micrometers in diameter. the fos provides higher sensitivity and resolutio n than currently used sensitized paper films and also allows real-time digital radiography when directly coupled to a commercially ava ilable ccd. the fiber optic plate used in the fos has excellent x-ray absorption characteristics, so that x-rays penetrating the x-ray scintil- lator and directly entering the ccd are minimized to less than 1 %. this protects the ccd from the deterioration and increased noise caused by x-ray irradiation, assuring a long service life and maintaining high image quality. various sizes and shapes of fos are available to meet your particular needs, including tapered fop types. x-ray image intensifier digital camera unit c7336-03 the c7336-03 consist of a high resolution, high contrast 4-inch x-ray image intensifier (x-ray i.i.) and a 1.45 megapixel digital ccd camera. the x-ray i.i. used has a fixed field-of-view of 100 mm diameter and an input window made of thin aluminum which is excellent in x-ray transmission and causes less scat- tering of x-rays. these features allow real-time detection at x-ray energy levels from about 20 kev. the 1.45 megapixel digital ccd camera captures high-quality images which are clear- er than those taken with conventional analog cameras. x-ray image intensifier camera unit (4-inch beryllium window) c7876, c7876-10 the c7876 is an x-ray image intensifier camera unit ideal for non-destructive inspec- tion of light-element materials and radiation imaging at low energy x-ray levels. the c7876 remarkably improves x-ray transmittance at low energy x-ray levels by us- ing a beryllium window instead of an aluminum window currently used for most x-ray image intensifiers. the results are sharp and clear, high contrast images taken in real time even at low energy x-ray levels down to a few kev. an aluminum window type is also available. x-cube (compact x-ray ccd camera) h8480, h8953, h8481 x-cube is a compact x-ray ccd camera designed for non-destructive inspection. using a general-purpose ccd chip mounted in a rugged but lightweight camera head, x-cube makes x-ray imaging as easy as an ordinary ccd camera in handling. left: h8480 center: h8953 right: h8481 2d image-device protection film fop (fiber optic plate) scintillator : csi(tl) txprf0005 tappf0174 tiif0170 tmcpf0072


▲Up To Search▲   

 
Price & Availability of L9421-02-15

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X